Instrumentation Cable

RE-Y(ST)Y-SINGLE & MULTI-PAIR


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Polyvinyl chloride PVC
    • Pairs: Twisted
    • Identification Pairs: Black & white, continuously numbered on white core (1, 2, 3…) for multi-element
    • Wrapping: 1 layer of PETP tape
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Cable Sheath: Polyvinyl Chloride PVC
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link

RE-Y(ST)Y PIMF – MULTI PAIR


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Polyvinyl Chloride PVC
    • Pairs: Twisted
    • Identification Pairs: Black & white, continuously numbered on white core (1, 2, 3…) for multi-element
    • Individual Screen: Aluminium / PETP tape over tinned copper drain wire, plastic tape under and above screen
    • Assembly: Concentric layers
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Cable Sheath: Polyvinyl chloride PVC
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link

RE-2X(ST)Y-SINGLE & MULTI PAIR


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Cross-linked polyethylene XLPE
    • Pairs: Twisted
    • Identification Pairs: Black & white, continuously numbered on white core (1, 2, 3…) for multi-element
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Cable Sheath: Polyvinyl chloride PVC (Also available in halogen free construction on request.)
    • Colour: Black. Blue for intrinsically safe system
    • Tinned copper braided screen, approx 85% coverage.
    • Special PVC outer sheath TM2, to EN 50363-4.1.
    • Colour grey (RAL 7032).

Catalogue Link

RE-2X(ST)Y PIMF MULTI-PAIR


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Cross-linked polyethylene XLPE
    • Pairs: Twisted
    • Identification Pairs: Black & white, continuously numbered on white core (1, 2, 3…) for multi-element
    • Individual Screen: Aluminium / PETP tape over tinned copper drain wire, plastic tape under and above screen
    • Assembly: Concentric layers
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Cable Sheath: Polyvinyl chloride PVC (Also available in halogen free construction on request.)
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link

RE-Y(ST)YSWAY-SINGLE & MULTI-PAIR


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Polyvinyl chloride PVC
    • Pairs: Twisted
    • Identification Pairs: Black & white, continuously numbered on white core (1, 2, 3…) for multi-element
    • Wrapping: 1 layer of PETP tape
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Inner Sheath: Polyvinyl chloride PVC
    • Armour: Galvanised round steel wires
    • Cable Sheath: Polyvinyl chloride PVC
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link

RE-Y(ST)YSWAY PIMF – MULTI-PAIR


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Polyvinyl chloride PVC
    • Pairs: Twisted
    • Identification Pairs: Black & white, continuously numbered on white core (1, 2, 3…) for multi-element
    • Assembly: Concentric layers
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Inner Sheath: Polyvinyl chloride PVC
    • Armour: Galvanised round steel wires
    • Cable Sheath: Polyvinyl chloride PVC
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link

RE-2X(ST)YSWAY-SINGLE & MULTI-PAIR


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Crosslinked polyethylene XLPE
    • Pairs: Twisted
    • Identification Pairs: Black & white, continuously numbered on white core (1, 2, 3…) for multi-element
    • Wrapping: 1 layer of PETP tape
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Inner Sheath: Polyvinyl chloride PVC
    • Armour: Galvanised round steel wires
    • Cable Sheath: Polyvinyl chloride PVC (Also available in halogen free construction on request.)
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link

RE-2X(ST)YSWAY PIMF – MULTI-PAIR


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • nsulation: Crosslinked polyethylene XLPE
    • Pairs: Twisted
    • Identification Pairs: Black & white, continuously numbered on white core (1, 2, 3…) for multi-element
    • Individual Screen: Aluminium / PETP tape over tinned copper drain wire, plastic tape under and above screen
    • Assembly: Concentric layers
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Inner Sheath: Polyvinyl chloride PVC
    • Armour: Galvanised round steel wires
    • Cable Sheath: Polyvinyl chloride PVC (Also available in halogen free construction on request.)
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link

RE-Y(ST)Y-MULTICORE


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Polyvinyl chloride PVC
    • Colour Code: Black, continuously numbered in white
    • Wrapping: 1 layer of PETP tape
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Cable Sheath: Polyvinyl chloride PVC
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link

RE-2X(ST)Y-MULTICORE


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Cross-linked polyethylene XLPE
    • Colour Code: Black, continuously numbered in white
    • Wrapping: 1 layer of PETP tape
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Cable Sheath: Polyvinyl Chloride PVC (Also available in halogen free construction on request.)
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link

RE-Y(ST)YSWAY-MULTICORE


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Polyvinyl chloride PVC
    • Colour Code: Black, continuously numbered in white
    • Wrapping: 1 layer of PETP tape
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Inner Sheath: Polyvinyl chloride PVC
    • Armour: Galvanised round steel wires
    • Cable Sheath: Polyvinyl Chloride PVC
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link

RE-2X(ST)YSWAY-MULTICORE


  • Cable Construction :
    • Conductor: Annealed copper wires according to BS EN 60228
    • Insulation: Cross-linked polyethylene XLPE
    • Colour Code: Black, continuously numbered in white
    • Wrapping: 1 layer of PETP tape
    • Collective Screen: Aluminium / PETP tape over tinned copper drain wire
    • Inner Sheath: Polyvinyl chloride PVC
    • Armour: Galvanised round steel wires
    • Cable Sheath: Polyvinyl Chloride PVC (Also available in halogen free construction on request.)
    • Colour: Black. Blue for intrinsically safe system

Catalogue Link